114.06.11 Taichung City Shude Small Classroom Illuminance Testing Project|Jinghong Inspection assists in campus lighting improvement


In response to the energy-saving policy and to improve the quality of the educational environment, Jianan Manufacturing Co., Ltd. commissioned Jinghong Inspection Technology on June 11, 114 to conduct a comprehensive classroom illuminance inspection service for Shude People's Primary School in South District, Taichung City. In this operation, the illuminance values of the classroom blackboards and desks are measured on the spot to check whether they comply with the CNS national lighting standards and the recommended guidelines of the Ministry of Education, and specific campus lighting improvement and energy-saving suggestions are proposed accordingly.

🔍 The importance of classroom illuminance detection

The classroom is the main space for students to study for a long time every day. Good lighting quality of educational space not only helps to improve learning efficiency, but also is related to students' visual health and physical and mental development. Through professional illuminance testing, schools can ensure that the lighting design meets the standard requirements, and detect lamp configuration problems or insufficient illuminance early, and then plan appropriate lighting improvement plans.

In addition, with the improvement of energy-saving regulations and procurement standards year by year, regular classroom lighting energy-saving assessments will also help schools to obtain relevant subsidies and achieve sustainable campus goals.

🛠 Execution content and measurement method

This illuminance test is performed by Jinghong Inspection's experienced technical team, using AA-level corrected illuminance meter and based on the following basis: Ministry of Education "School Lighting Energy-saving Improvement Reference Manual" (101 edition), CNS 5065 "Indoor Lighting Standard", CNS 12112 "Lighting Design Benchmark"

Blackboard illuminance measurement

Set up points C, D, and E according to 30 cm up and down the central vertical midline, and extend 100 cm to the left and right to set points A, B, F, G, etc. , A total of 7 points are calculated on average to confirm whether it has reached750 LuxThe recommended illuminance standard.

Desktop illuminance measurement for each lesson

Based on the height of the desk at 72 cm, 9 measurement points are set up at the four corners, midline, and center of the classroom to calculate the overall average illuminance and check whether it reaches the target.500 LuxThe above basic needs.

LED measurement results and lighting improvement recommendations

After on-site illuminance measurement, all test points have met the requirements of the standard specification, and the first test meets the requirements without supplementary testing or improvement.

Although the current illuminance has met the specifications, in order to ensure the long-term lighting quality, the maintenance recommendations are as follows:

  • Clean the lamps and reflective surfaces regularly to avoid dust accumulation affecting brightness
  • Establish an annual illuminance detection mechanism to track aging or brightness attenuation

Through this campus lighting testing and evaluation service, it not only helps schools improve the quality of teaching space, but also promotes the achievement of overall energy-saving goals.

*Key services: classroom illuminance testing, campus lighting energy saving, CNS illuminance standard consultation, teaching space light environment improvement

Jinghong Inspection is committed to providing professional, compliant and sustainability-oriented lighting inspection and improvement recommendation services to assist schools, educational institutions and government units at all levels to create safe, comfortable and efficient green learning spaces.

📩 If you need to arrange campus lighting inspection or learn more about the service, please contact us.

For inquiries, please contact: Ms. Wang, JHEt (05)599-0970~72
Email: [email protected]